Windows

8225TL Thermal Windows

The 8225TL Thermal Windows combine design flexibility and high performance, offering engineering and superior aesthetics that last. Adaptable to every building envelope and design possibility, the 8225TL Windows meets every need.

  • 2-1/4″ (57.2mm) depth
  • Architectural window (AW)
  • Thermal performance
  • Fixed, casement or projecting configuration
  • Hurricane resistance
  • Available as projected, casement and fixed
  • Tested for performance class and grade of HC90 and AW90
  • 2-1/4″ (57.2mm) frame depth and 0.090″ (2.3mm) nominal wall thickness
  • Overlap vent design
  • IsoLock™ thermal break mechanically and adhesively bonds the thermal break material to the aluminum frame and prevents dry shrinkage
  • Cast white bronze cam locks and keepers
  • Optional dual glazing with or without Venetian blinds
  • Optional factory glazing
  • Large and small missile impact tested for fixed and project out configurations

Hurricane Resistant

Find out more here.

Thermal Technology

Find out more here.

Related Product Approvals

Find out more here.

8225TL Thermal Window - Architectural Detail Manual
8 MB
8225TL Thermal Window - Architectural Detail Manual (French Canadian)
8 MB
Product Selection Guide Windows
588 KB
Product Selection Guide Hurricane Resistant Windows
472 KB
Product Selection Guide Blast Mitigation Windows
186 KB
8225TL Thermal Window - Flyer
561 KB
Kawneer Window Accessories
302 KB
Florida Product Approval & Texas Dept. of Insurance Evaluation Documents
290 KB
Fixed & Ribbon Windows/Aluminum Windows - EPD
604 KB
Projected & Casement Windows/Aluminum Windows -EPD
893 KB
Finishes Brochure
5 MB
Finishes Information - Architectural Detail Manual
238 KB
Anodize Finishes - Color Chart
82 KB
Liquid Paint - Color Chart - Permadize®
794 KB
Liquid Paint - Color Chart - Permafluor™
350 KB
8225TL Thermal Casement Window - English
8225TL Thermal Casement Window - French
8225TL Thermal Fixed Window - English
8225TL Thermal Fixed Window - French
8225TL Thermal Projected Window - English
8225TL Thermal Projected Window - French

Download All
Fixed Details
Fixed Beside Fixed with Stack Mullion Details
Fixed with Horizontal Details
Fixed Over Fixed with Stack Horizontal Details
Fixed with Blinds Details
Fixed with Muntin Grid Details
Project-In Details
Project-In Beside Project-In Details
Fixed Beside Project-In Details
Fixed Over Project-In Details
Project-In Beside Project-In with Stack Mullion Details
Fixed Beside Project-In with Stack Mullion Details
Fixed Over Project-In Beside Fixed Over Project-In with Stack Mullion Details
Project-In with Blinds Details
Project-In with Muntin Grid Details
Project-Out Details
Project-Out Beside Project-Out Details
Fixed Beside Project-Out Details
Fixed Over Project-Out Details
Project-Out Beside Project-Out with Stack Mullion Details
Fixed Beside Project-Out with Stack Mullion Details
Fixed Over Project-Out Beside Fixed Over Project-Out with Stack Mullion Details
Project-Out with Blinds Details
Project-Out with Muntin Grid Details
Inswing Casement Details
Fixed Beside Inswing Casement Details
Inswing Casement Beside Inswing Casement Details
Inswing Casement Beside Inswing Casement with Stack Mullion Details
Inswing Casement with Blinds Details
Inswing Casement with Muntin Grid Details
Outswing Casement Details
Fixed Beside Outswing Casement Details
Outswing Casement Beside Outswing Casement Details
Outswing Casement Beside Outswing Casement with Stack Mullion Details
Outswing Casement with Blinds Details
Outswing Casement with Muntin Grid Details
Receptor and Full Depth Subsill Details
Perimeter Filler, Anchors, and Subsill Details
Hurricane Impact Fixed Details
Hurricane Impact Project-Out Details
Hurricane Impact Fixed Over Project-Out Details
Hurricane Impact Casement Outswing Details
Download All

While most of our products are not hazardous in and amongst themselves, hazardous properties can develop when the product is altered through cutting, welding, and grinding.  Details on the specific hazards that can develop and the proper protective measures to use can be found in the SDSs.

Arconic’s SDS database provides PDF files of safety information on specific materials.  The SDS ID numbers (product code) and description for materials used in Kawneer products are listed below.

SDS # DESCRIPTION / TITLE
1405 – Kawneer Thermal Break Filled Extrusions
1385 – Kawneer Acrylic Paints
1386 – Kawneer Fluoropolymer Paints

1526 – Kawneer Bloomsburg Solvent Recovery Still Residuals

1387 – Painted Architectural Aluminum Extrusions
509 – Aluminum Extrusions, Anodized Aluminum Products

 

Search Arconic’s SDS database for safety information on specific materials.

 

Warranty Disclaimer TBC

Project Warranty Cover Sheet (English)
137 KB
Project Warranty Cover Sheet (French-Canadian)
137 KB
Project Warranty Cover Sheet Sample (English)
139 KB
Project Warranty Cover Sheet Sample (French-Canadian)
140 KB
Material & Workmanship - English
185 KB
Material & Workmanship - French
190 KB
Material & Workmanship Sample (English)
203 KB
Material & Workmanship Sample (French Canadian)
212 KB
Anodized Finishes Warranty - English
523 KB
Anodized Finishes Warranty - French
517 KB
Anodized Finishes Sample (English)
529 KB
Anodized Finishes Sample (French Canadian)
524 KB
Painted Finishes Warranty - English
557 KB
Painted Finishes Warranty - French
538 KB
Painted Finishes Sample (English)
565 KB
Painted Finishes Sample (French Canadian)
550 KB
Insulating Glass Warranty - English
498 KB
Insulating Glass Warranty - French
499 KB
Insulating Glass Sample (English)
502 KB
Insulating Glass Sample (French Canadian)
504 KB
Laminated Glass Warranty - English
122 KB
Laminated Glass Warranty - French
123 KB
Laminated Glass Sample (English)
126 KB
Laminated Glass Sample (French Canadian)
128 KB
Corrective Field Repairs (English)
154 KB
Corrective Field Repairs (French-Canadian)
152 KB